Product Details:
Place of Origin: CHINA
Brand Name: WINTEAM
Certification: ISO9001
Model Number: M serise
Payment & Shipping Terms:
Minimum Order Quantity: one box
Price: Negotiable
Packaging Details: paper box
Contact Now
Detailed Product Description
Name: Millipore Membrane Filter Material: MCE
Packing: 600pc/box Surface: Grid
Sterility: Gamma Port: Shanghai
High Light:

mce membrane filter

,

teflon mesh filter

 

water filter membrane Microporous Membrane Filter grid glossy PE NYLON

Microporous Membrane Filter.pdf

 

1. The nominal pore size of the membrane must be accurately selected according to the needs before use. The filtered material must be larger than the nominal pore size of the membrane (except for the particles with a pore size of 0.65, 0.8, 1.2 microns; except for bacteria with a nominal pore size of 0.22, 0.45). Micron). 2. The membrane should be cleaned before use. It should be washed with distilled water and then placed in the filter. 3. When there are many particles and bacteria in the filtrate, it should be filtered, that is, filtered with a filter medium or a large pore filter to avoid excessive blockage. 4, a lot of disinfection methods, generally using hot pressing disinfection, that is, steam sterilization at 120 ° C for 30 minutes, when hot pressure disinfection, should avoid direct steam unidirectional on the membrane, and prevent the negative pressure caused by steam condensation and the back of the film Pressure and damage. Boiling disinfection, chemical disinfection, etc. 5, sterilization and filtration is best to use the bubble method to test whether the seal is tight, whether the filter is damaged due to improper disinfection, bubble point pressure see the quality of the interim standard. 6. When filtering liquid, the filter must be wet. If the filter is dry due to disinfection, it must be wetted with sterile water. If the wetting does not affect the flow rate, all filter membranes must be applied before sterilization. Disinfection, and then in the sterile room for sterilization filtration, should be carried out in strict accordance with the sterilization protocol, using a nominal pore size of 0.22, 0.45 micron filter, E. coli using a nominal pore size of 0.65 microns. 7. The membrane is flammable and resistant to acid and alkali. It is not resistant to solvents. It is only suitable for aqueous solution (PH5-10) oil, air, juice, alcohol, etc. Before use, it must be known whether the filter material has an effect on the membrane. 8. When the filtrate is below 0.22 μm, it is not suitable to use microporous membrane filtration; for the heat source virus, it only has adsorption and cannot be completely removed. 9. When using 150 closed filter, the liquid should be put into the filter, and the original air inside should be discharged (there is a venting pipe on the upper), otherwise the filtration speed will be affected.

 

Φ50 water system MCE (mixed cellulose) 0.22μm/0.45μm microporous membrane

Φ50 water system MCE0.22μm/0.45μm microporous membrane

Microporous membranes include, mixed cellulose (MCE), cellulose acetate (CA), nylon (PA/NYLON), polypropylene (PP), polyethersulfone (PES), polyvinylidene fluoride ( PVDF) material, PTFE material, polycarbonate (PC film, nuclear perforated) material, glass fiber (GLASS FIBER) material. It is mainly used for sample analysis, especially filtration of mobile phase and sample in chromatographic analysis. It has a good effect on protecting the column and infusion pump piping system and injection valve from contamination. It has been widely used in gravimetric analysis, microanalysis, colloid separation and sterility experiments.

 

  • Individual package with pre-sterilization for improving of testing reliability
  • Gamma ray sterilization with zero residual
  • Imported medical dialysis package

 

Parameter:

 

Model diameter density Material Surface packing
M47 47mm 0.45μm (MCE) Glossy 100pc/box,600pc/box
M47A 47mm 0.45μm (MCE) grid 100pc/box,600pc/box
M47B 47mm 0.45μm (Nylon) Glossy 100pc/box,600pc/box
M47C 47mm 0.45μm (PP) Glossy 100pc/box,600pc/box
M47D 47mm 0.22μm (MCE) Glossy 100pc/box,600pc/box
M50 50mm 0.45μm (MCE) Glossy 100pc/box,600pc/box
M50A 50mm 0.45μm (MCE) grid 100pc/box,600pc/box
M50B 50mm 0.45μm (Nylon) Glossy 100pc/box,600pc/box
M50C 50mm 0.45μm (PP) Glossy 100pc/box,600pc/box
M60 60mm 0.45μm (MCE) Glossy 100pc/box,600pc/box
M60A 60mm 0.45μm (MCE) grid 100pc/box,600pc/box
M60B 60mm 0.45μm (Nylon) Glossy 100pc/box,600pc/box
M60C 60mm 0.45μm (PP) Glossy 100pc/box,600pc/box

 

Φ50 water system MCE0.22μm/0.45μm microporous membrane

Microporous membranes include, mixed cellulose (MCE), cellulose acetate (CA), nylon (PA/NYLON), polypropylene (PP), polyethersulfone (PES), polyvinylidene fluoride ( PVDF) material, PTFE material, polycarbonate (PC film, nuclear perforated) material, glass fiber (GLASS FIBER) material. It is mainly used for sample analysis, especially filtration of mobile phase and sample in chromatographic analysis. It has a good effect on protecting the column and infusion pump piping system and injection valve from contamination. It has been widely used in gravimetric analysis, microanalysis, colloid separation and sterility experiments.

 

Microporous membranes are indispensable consumables for pharmaceutical microbiological testing and some small-scale liquid filtration. Our company now offers a variety of materials, microporous membranes of different diameters and pore sizes, can be used with different types of membrane filters or filter holders, widely used in a variety of liquid sterility, limit inspection or sterilization, degranulation and so on.

 