Hangzhou Winteam Scientific Instruments Co., Ltd.
THE MISSION OF WINTEAM IS PROVIDE BETTER STERILITY TEST PRODUCTION
Place of Origin: | CHINA |
Brand Name: | WINTEAM |
Certification: | ISO |
Model Number: | YT-V800 |
Minimum Order Quantity: | ONE SET |
---|---|
Price: | Negotiable |
Packaging Details: | wooden case |
Supply Ability: | 20 sets one month |
Name: | Hydrogen Peroxide Sterilization | Tank: | 27L |
---|---|---|---|
Sterilizing Agent: | H2O2 | Warranty: | 1 Year |
Color: | Silver | Display: | LCD Display |
High Light: | hydrogen peroxide equipment,hydrogen peroxide vapor machine |
hydrogen peroxide sterilization equipment Ghp sterilization simens PLC
Hydrogen Peroxide Sterilization .pdf
working principle
Vaporized hydrogen peroxide sterilization is the advantage of utilizing hydrogen peroxide at a normal temperature to have a more spore-killing ability than a liquid state. The liquid H2O2 is vaporized and rapidly formed into a free hydroxyl group (HO--) for attacking. Cellular components, including lipids, proteins, and DNA tissues, destroy their structure and achieve complete sterilization requirements.
The vaporized hydrogen peroxide sterilizer vaporizes the H2O2 solution with a concentration of 35%, that is, hydrogen peroxide, into a hydrogen peroxide vapor through a vaporizer, and then converts the particles into a gas HO- through a plasma, and delivers it to the space for sterilization. device of.
work process
The biological decontamination process of a plasma vaporized hydrogen peroxide sterilizer can be divided into four stages:
1. Vaporization stage: the hydrogen peroxide solution is input into a vaporizer to be vaporized into hydrogen peroxide vapor, and is input to the mixing chamber through a fan, waiting for processing;
2. Plasma generation stage: introducing steam hydrogen peroxide into the plasma generation chamber, converting the steam hydrogen peroxide into plasma hydrogen peroxide, and feeding it into the sterilization chamber;
3. Biological decontamination maintenance stage: continue to input hydrogen peroxide plasma into the sterilization chamber until the preset concentration (generally based on the biological test paper verification concentration value) is started, and the temperature is maintained above the preset concentration. 35min, biological decontamination completed (provided that the sterilization efficiency reached 6-log in 30min), stopping hydrogen peroxide vaporization and plasmaization;
4. Residual stage: The gas path system switches to the residual device, and the hydrogen peroxide that vaporizes the plasma is converted into water and oxygen through the decomposer, and the circulation continuously reduces the concentration of hydrogen peroxide in the air to less than 1 ppm.
Dimensions | 560*720*1000mm (length × width × height) |
Noise | ≤70dB(A) |
Sterilized air flow | ≤2.4m3/min |
Injection rate | 0 ~ 20g / min |
Vaporization temperature | ≤100°C |
Dehumidification humidity | ≤30%RH |
Sterilization space | ≤50m3 |
Sterilizer | 35% food grade hydrogen peroxide solution |
Sterilizer capacity | 500g |
Dehumidifying agent | molecular sieve |
Kill rate | The ability to kill a thermophilic fat spore is 106 |
Working method | continuous work |
Configuration of the wireless remote controller is able to remote control devices starting and
Introduce biosafety laboratories, laboratory animal centers, GMP research in pharmaceutical plants, and contain circulatory systems, which require daily disinfection and sterilization.
Space-sprayed hydrogen peroxide sterilization system sterilizes all spaces and cleans the surface area by using a spore-killing dry mist gasification method, and eliminates the space of the clean sterile area of the drug customer by a professional sterilization program. A complete set of clean, convenient, environmentally friendly, safe, and challenging tests for bacterial spore biological indicators can achieve the best path to 10^3-10^6 killing. The most important characteristics of atomized hydrogen peroxide sterilization are: good performance, long service life, no other pain, environmental damage, good practicability, and complete maintenance.
In addition, there are are operating videos for our products for the convenience of customers to use.
Contact Person: Mr. wong
Tel: 86-158 6910 9373
Fax: 86-0571-85229935
One - Off Sterility Test Canister Unit Pharmaceutical Factory Use Silicon Rubber Cap
Single Use Sterility Peristaltic Test Device Pump , Sterility Test Device 48 Sets / Box
Millipore Level Sterility Test Device , Lab Steritest System PVC Tube
304 SS Automatic Sterility Test Pump Low Noisy 17kg Pump Speed 15-240rpm
Safety Sterility Testing Hardware , Sterility Test Device With Printer Test Pump
Customized Type Sterility Testing Accessories , Sterility Test Kit Electronic Power
Transfer Dispensing Isolator , 220v 50hz Cleanroom Containment Isolator
A Air Classification Sterilization System , 304 SS Cleanroom Isolator
Positive Pressure Isolator , Commercial Sterility Test Soft PVC Chamber